R/wrcc_EBAMQualityControl.R
wrcc_EBAMQualityControl.Rd
Perform various QC measures on WRCC EBAM data.
The any numeric values matching the following are converted to NA
x < -900
x == -9.9899
x == 99999
The following columns of data are tested against valid ranges:
Flow
AT
RHi
ConcHr
A POSIXct datetime
column (UTC) is also added based on DateTime
.
wrcc_EBAMQualityControl( tbl, valid_Longitude = c(-180, 180), valid_Latitude = c(-90, 90), remove_Lon_zero = TRUE, remove_Lat_zero = TRUE, valid_Flow = c(16.7 * 0.95, 16.7 * 1.05), valid_AT = c(-Inf, 45), valid_RHi = c(-Inf, 50), valid_Conc = c(-Inf, 5000), flagAndKeep = FALSE )
tbl | single site titbble created by |
---|---|
valid_Longitude | range of valid Longitude values |
valid_Latitude | range of valid Latitude values |
remove_Lon_zero | flag to remove rows where Longitude == 0 |
remove_Lat_zero | flag to remove rows where Latitude == 0 |
valid_Flow | range of valid Flow values |
valid_AT | range of valid AT values |
valid_RHi | range of valid RHi values |
valid_Conc | range of valid ConcHr values |
flagAndKeep | flag, rather than remove, bad data during the QC process |
Cleaned up titbble of WRCC monitor data.